Category: EPA-4

EPA 4C: Partial Edentulous Fixed Partial Denture - Implant Supported

Partial Edentulous Fixed Partial Denture - Implant Supported
Meets Expectations of the Graduate
Progressing
Below Expectations
Critical Error

Isolation and Soft Tissue Management

  • No iatrogenic damage to soft peri-implant soft tissue
  • Throat pack used during placement and removal of implant components/ restoration
  • Minimal tissue damage consistent with placement and removal of implant coping
  • Soft tissue damage inconsistent with procedure
  • Missing throat pack
  • Gross iatrogenic damage to peri-implant soft tissue due to repeated placement and removal of coping
  • Significant soft tissue damage requiring specialized care (e.g. sutures)

IMPRESSION

Impression coping placement

  • Impression coping seated completely and verified with a radiograph
  • Impression coping seated completely but screw
  • Missing verification radiograph
  • Impression coping incompletely seated
  • Coping screw torqued with a torque wrench or fractured coping
  • Failure to place healing abutment back on

Impression

  • Peri implant soft tissue cuff accurately captured.
  • Coping is stable within the completed impression
  • All teeth accurately captured without voids/distortion/ burn through
  • Appropriate impression coping, impression materials and tray selection
  • Adequate opposing arch record and accurate inter-occlusal record
  • Minor void present along peri implant tissue that will not affect implant crown fit
  • Final impression/ opposing arch impression shows minor voids/ distortion/ burn through in non-critical areas
  • Final impression/ opposing arch impression shows major voids/ distortion/ burn through in non-critical areas
  • Voids/ distortion in critical areas of peri implant tissue or remaining teeth (proximal surface of adjacent teeth or occlusal surfaces).
  • Coping unstable within completed impression
  • Inappropriate impression coping, impression materials or tray selection
  • Inadequate/ missing opposing arch impression/ interocclusal record that precludes implant crown fabrication

RESTORATION (PROVISIONAL/ DEFINITIVE)

Abutment and or Crown fit and stability

  • Complete seating with stable, passive fit. Verified with a radiograph
  • Stable with light premature soft tissue or proximal interferences till complete seating
  • Stable with significant premature interferences till complete seating: needs recontouring
  • Incomplete seating with severe rocking/ rotation. Learner recognized the need to re-impress. Missing verification radiograph.

Occlusal Anatomy and Contacts

  • Anatomy conforms to existing tooth form
  • Multiple centric contacts present with ideal intensity and location. Restored with mutually protected occlusal scheme
  • Anatomy lacks definition
  • Light/ heavy or insufficient centric contacts present
  • Significant deviation in anatomy in some areas
  • Premature occlusal contacts in centric or interferences in balancing or non-functional movements
  • Anatomy absent
  • Gross hyper occlusion or infra-occlusion

Surface Contour, Proximal Contacts and Finish (inclusive of screw access restoration)

  • Ideal anatomic contours, marginal integrity and embrasures
  • Convex proximal contacts that are visibly closed, appropriately located with the right intensity
  • Highly polished surface
  • Slightly over/ under contoured surface
  • Proximal contacts are visibly closed but lack intensity or show slight variation in location
  • Crown surface slightly rough in finish
  • Decidedly over/ under-contoured surface or presence of soft tissue impingement
  • Concave, irregular or tight proximal contacts
  • Crown surface decidedly rough or pitted
  • Grossly over or under-contoured
  • Proximal contact visually open
  • Crown surface deeply pitted or grooved

Screw access restoration

  • Abutment screw torqued as directed by manufacturer. Seating verified with radiograph
  • Access sealed with teflon and restorative material under adequate isolation
  • Slight variation in access restoration thickness
  • Inadequate/ excess access restoration thickness
  • Absence of post cementation radiograph
  • Incorrect manufacturer’s torque wrench used or over/ under torque of screw
  • Missing teflon tape/ inadequate isolation maintained

Cementation

  • Appropriate cementation protocol used under adequate isolation
  • Absence of residual cement, verified with radiograph
  • Minor debris of residual cement
  • Absence of post cementation radiograph
  • Inappropriate cementation protocol used or inadequate isolation maintained
  • Gross presence of residual cement
  • Incorrect manufacturer’s kit used or over/ under torque of screw