Tooth Modifications

  • Appropriate location and dimensions of modifications with adequate occlusal clearance
  • Guiding surfaces parallel to path of insertion
  • All modifications completed per approved design. Modified surface has a smooth polish
  • No residual caries/ defective restorations/ missing survey crowns
  • Slight deviation in location and dimensions with modifications limited to enamel
  • Modified surface lacks finish
  • Significant deviation in location. Over preparation extending to the DEJ or under preparation 0.5 - 1mm depth
  • Inadequate occlusal clearance corrected by minor opposing enameloplasty
  • Surface decidedly rough or pitted
  • Gross deviation in location and extensions: overpreparation into dentin (restoration) or under preparation compromising framework integrity (< 0.5mm depth)
  • Inadequate occlusal clearance that causes increase in VDO
  • Missing modifications or no uniform path of insertion
  • Surface deeply pitted or grooved
  • Presence of residual caries/ defective restorations/ missing survey crowns

Impressions

  • All critical landmarks captured: impression free of voids/ distortion/ burn through
  • Borders properly extended: the material should extend to the depth of the vestibule without displacing tissues
  • Appropriate impression materials and tray selection
  • Adequate opposing arch record
  • Minor voids/ distortion/ burn through in non-critical areas
  • Borders overextension can be corrected with altered cast impression
  • Major voids/ distortion/ burn through in non-critical areas
  • Inadequate capture of critical landmarks or voids/ distortion in critical areas
  • Border grossly over/ underextended
  • Inappropriate impression material or tray selection
  • Inadequate/ missing opposing arch impression

Framework Try-in

  • Stable, complete seating of framework
  • Occlusal contacts based on planned occlusal scheme maintained/ established
  • Adjusted surface of framework polished
  • Framework causes minor hyper occlusion: opposing minor enameloplasty without appropriate diagnosis
  • Adjusted surface of framework lacks finish
  • Framework causes hyper occlusion: opposing moderate enameloplasty without appropriate identification /diagnosis
  • Adjusted surface of framework pitted/ grooved
  • Unstable, incomplete seating of framework without identifying and planning a remake
  • Framework causes severe hyper occlusion without appropriate identification /diagnosis
  • Adjusted surface of framework deeply pitted or grooved

MMR / Tooth Try-In

Rims or try-in adjusted to establish the following records:

  • correct centric relation
  • appropriate vertical dimension of occlusion (VDO)
  • Sufficient soft tissue support
  • Appropriate esthetic evaluation
  • Ideal phonetics: Clear speech
  • Rims or try-in stable and bonded
  • Occlusal contacts established based on planned occlusal scheme

Rims or try-in adjusted for the following records:

  • Centric relation and VDO is close but may be slightly off and can be corrected at a subsequent step
  • Soft tissue support slightly excessive/ inadequate but can be corrected at an appropriate step
  • Esthetics slightly off but within acceptable range
  • Speech slightly unclear but within acceptable range
  • Some occlusal contacts are missing but can be adjusted chairside or learner requested for lab correction

Rims or try-in adjusted for the following records:

  • Centric relation or VDO is incorrect. Learner able to evaluate but could not address
  • Inadequate/ excess soft tissue support. Learner able to evaluate but could not address
  • Esthetics not ideal. Learner able to evaluate but could not address
  • Difficulty with speech. Learner able to evaluate but could not address
  • Occlusal scheme or contacts not ideal. Learner able to evaluate but could not address

Rims or try-in adjusted for the following records:

  • Centric relation or VDO is grossly incorrect. Learner unable to evaluate
  • Grossly inadequate/ excess soft tissue support. Learner unable to evaluate and address
  • Smile display unacceptable. Learner unable to evaluate and address
  • Pronounced difficulty with speech due to inappropriate rim/ tooth position. Learner unable to evaluate and address
  • Inability to evaluate rims/try-in or make records due to instability or debonding.
  • Occlusal scheme not ideal: Inadequate occlusal contacts or gross premature interferences in centric and excursive movements

Insertion / Post-insertion

  • Prosthesis is fully seated.
  • Intaglio evaluated and adjusted for pressure spots/ prosthesis extension
  • Occlusal scheme is ideal and occlusion is appropriately equilibrated
  • Adjusted surfaces of prosthesis polished
  • Home-care instructions discussed
  • Patient indicates comfort, can insert and remove prosthesis
  • Centric relation, vertical dimension of occlusion (VDO), Esthetics, and Phonetics are appropriate and acceptable
  • Small interference or undercut remains, but able to seat
  • Mild pressure spots/ prosthesis extensions remain that can be corrected at the following appointment
  • Some contacts missing, but bilateral contacts exist
  • Adjusted surfaces of prosthesis lacks finish
  • Centric relation, vertical dimension of occlusion (VDO), Esthetics, and Phonetics, are within acceptable range
  • Issues with seating of prosthesis/ prosthesis extension/ occlusion beyond clinical acceptable range or presence of pressure spots. Learner able to evaluate but could not address
  • Quality of prosthesis (CR/ VDO/ Esthetics/ Phonetics) beyond clinical acceptable range. Learner able to evaluate but could not address
  • Adjusted surfaces of prosthesis rough
  • Gross issues with seating of prosthesis/ prosthesis extension/ Presence of pressure spots. Learner unable to evaluate and address Occlusal scheme not ideal: Inadequate occlusal contacts or gross premature interferences in centric and excursive movements
  • Adjusted surfaces of prosthesis deeply pitted or rough
  • Failure to provide home-care instructions
  • Failure to address patient’s discomfort or inability to seat/remove prosthesis
  • Unacceptable quality of prosthesis (CR/ VDO/ Esthetics/ Phonetics). Learner unable to evaluate and address

Implant assisted RPD Insertion

  • Abutment correctly selected
  • Abutment seated completely and torqued to manufacturer’s recommendation
  • Intaglio adequately adjusted to create clearance for locator pick up
  • Abutment pick up completed using spacers and appropriate pick-up material.
  • Excess flash removed and surface finished and polished
  • Housing stable within the denture. Appropriate insert placed based on patient dexterity
  • Slight deviation in abutment height selection
  • Slight deviation in intaglio clearance
  • Intaglio surface lacks finish
  • Patient is unable to remove prosthesis or finds it loose: learner can identify issue with retention insert selection
  • Excess clearance created for abutment pick up
  • Intaglio surface decidedly rough
  • Patient is unable to remove prosthesis or finds it loose: learner is unable to identify issue with retention insert selection
  • Excessive height of abutment that violates minimum denture thickness (<2mm)
  • Abutments are incorrectly seated. Excess or inadequate torque applied.
  • Incompatible prosthetic components used.
  • Gross adjustment of intaglio compromising denture integrity
  • Inappropriate pick-up material used. denture locked intra-orally due to missing spacers
  • Intaglio surface deeply pitted or rough
  • Housings do not engage/ prosthesis does not seat completely or is unstable post pick up